©2024 - Webber Electronics

CALL US 440.327.7200
 

Technical Info

Cordage Types

print
SPT Rated Voltage: 300V Rated Temp: 60c , 105c        
 
Cable Type AWG AMP/VOLT No. of Conductors Conductors PVC Insulation  
Cross Section Stands Thickness O.D.  
2/C 3/C  
SPT-1 20 10A 125V 2 or 3 See End of Table 0.519 27 / 0.160 0.76 2.55X4.90 2.8X7.6  
18 0.823 41 / 0.160 0.85 2.76X5.35 3.0X8.0  
SPT-2 18 10A 125V 0.823 41 / 0.160 1.2 3.50X6.85 3.6X8.5  
16 13A 125V 1.21 65 / 0.160 1.2 3.80X7.30 3.9X9.3  
SPT-3 18 10A 250V 0.823 41 / 0.160 1.6 4.60X8.90 4.4X10.4  
16 13A 250V 1.31 65 / 0.160 1.6 4.70X9.10 4.7X10.8  
14 15A 250V 2.08 41 / 0.254 2 6.10X11.90 6.0X13.5  
All Dimensions in MM  
                   
                   
                   
                   
NISPT Rated Voltage: 300V Rated Temp: 60c , 105c Non-Integral
Cable Type AWG AMP/VOLT No. of Conductors Conductors Insulation Outer Jacket
Cross Section Stands Thickness O.D. Thickness O.D.
NISPT-2 18 10A 125V 2 0.823 41 / 0.160 0.76 2.75 0.38 3.8X7.3
16 13A 125V 2 1.21 65 / 0.160 0.76 3 0.38 4.0X7.7
All Dimensions in MM
                   
                   
                   
SVT Rated Voltage: 300V Rated Temp: 60c , 105c Dimensions Apply To All SVT Cable Types Including: SVT & SVTO
Cable Type AWG AMP/VOLT No. of Conductors Conductors Insulation Outer Jacket
Cross Section Stands Thickness O.D. Thickness O.D.
SVT 18 10A 125V 2 0.823 41 / 0.160 0.38 2.1 0.76 6.3
3 0.823 41 / 0.160 0.38 2.1 0.76 6.4
All Dimensions in MM
                   
SJT Rated Voltage: 300V Rated Temp: 60c , 105c Dimensions Apply To All SJT Cable Types Including: SJT, SJTW, SJTO, SJTOW, SJTOOW, SJE, SJEW, SJEW, SJEO, SJEOW, SJEOOW
Cable Type AWG AMP/VOLT No. of Conductors Conductors Insulation Outer Jacket
Cross Section Stands Thickness O.D. Thickness O.D.
SJT 18 10A 125V 2 0.823 41 / 0.160 0.85 2.9 0.95 7.5
3 0.823 41 / 0.160 0.85 2.9 0.95 7.8
4 0.823 41 / 0.160 0.85 2.9 0.95 9
16 13A 250V 2 1.31 65 / 0.160 0.85 3.2 0.95 8.3
3 1.31 65 / 0.160 0.85 3.2 0.95 8.5
4 1.31 65 / 0.160 0.85 3.2 0.95 9.8
14 15A 250V 2 2.08 41 / 0.254 0.85 3.6 0.95 9.2
3 2.08 41 / 0.254 0.85 3.6 0.95 9.6
4 2.08 41 / 0.254 0.85 3.6 0.95 10.6
12 20A 250V 3 3.31 66 / 0.254 0.38 4.1 0.95 11.5
All Dimensions in MM
                   
ST Rated Voltage: 300V Rated Temp: 60c , 105c Dimensions Apply To All SVT Cable Types Including: ST, STW, STO, STOW, SE, SEW, SEO, SEOW
Cable Type AWG AMP/VOLT No. of Conductors Conductors Insulation Outer Jacket
Cross Section Stands Thickness O.D. Thickness O.D.
ST 18 10A 125V 2 0.823 41 / 0.160 0.85 2.9 1.7 9.2
3 0.823 41 / 0.160 0.85 2.9 1.7 9.7
4 0.823 41 / 0.160 0.85 2.9 1.7 10.4
16 13A 250V 2 1.31 65 / 0.160 0.85 3.2 1.7 9.8
3 1.31 65 / 0.160 0.85 3.2 1.7 10.3
4 1.31 65 / 0.160 0.85 3.2 1.7 11.1
14 15A 250V 2 2.08 41 / 0.254 1.2 4.3 2.2 13
3 2.08 41 / 0.254 1.2 4.3 2.2 13.7
4 2.08 41 / 0.254 1.2 4.3 2.2 14.8
12 20A 250V 2 3.31 64 / 0.254 1.2 4.8 2.6 14.8
3 3.31 64 / 0.254 1.2 4.8 2.6 15.5
4 3.31 64 / 0.254 1.2 4.8 2.6 16.8
10 30A 250V 2 5.261 66 / 0.320 1.2 5.4 2.7 16.2
3 5.261 66 / 0.320 1.2 5.4 2.7 17
4 5.261 66 / 0.320 1.2 5.4 2.7 18.4
All Dimensions in MM
                   
HO3VV-F   Rated Temp: 60c , 105c International Cable Type
Cable Type Rated Voltage No. of Conductors Conductors Insulation Outer Jacket
Cross Section Stands Thickness O.D. Thickness O.D.
HO3VV-F 300 / 300 2 0.75 24 / 0.20 0.5 2.2 0.6 5.6
300 / 300 3 0.75 24 / 0.20 0.5 2.2 0.6 6
All Dimensions in MM
                   
                   
HO5VV-F   Rated Temp: 60c , 105c International Cable Type
Cable Type Rated Voltage No. of Conductors Conductors Insulation Outer Jacket
Cross Section Stands Thickness O.D. Thickness O.D.
HO5VV-F 300 / 500 2 0.75 24 / 0.20 0.6 2.4 0.8 6.6
2 1 32 / 0.20 0.6 2.6 0.8 7
2 1.5 30 / 0.25 0.7 3 0.8 7.8
2 2.5 50 / 0.25 0.8 3.6 1 9.4
3 0.75 24 / 0.20 0.6 2.4 0.8 7
3 1 32 / 0.20 0.6 2.6 0.8 7.4
3 1.5 30 / 0.25 0.7 3 0.9 8.5
3 2.5 50 / 0.25 0.8 3.6 1 10.5
All Dimensions in MM
                   
                   
HO3VVH2-F Non-Integral Rated Temp: 60c , 105c International Cable Type
Cable Type Rated Voltage No. of Conductors Conductors Insulation Outer Jacket
Cross Section Stands Thickness O.D. Thickness O.D.
HO3VVH2-F 300 / 500 2 0.5 16 / 0.20 0.5 2.2 0.6 3.2X5.3
2 0.75 24 / 0.20 0.5 2.2 0.6 3.2X5.6
All Dimensions in MM
                   
                   
HO5VVH2-F Non-Integral Rated Temp: 60c , 105c International Cable Type
Cable Type Rated Voltage No. of Conductors Conductors Insulation Outer Jacket
Cross Section Stands Thickness O.D. Thickness O.D.
HO5VVH2-F 300 / 500 2 0.75 24 / 0.20 0.6 2.4 0.8 4.1X6.5
2 1 32 / 0.20 0.6 2.6 0.8 4.3X6.9
2 1.5 30 / 0.25 0.7 3 0.8 4.7X7.7
All Dimensions in MM
                   
                   
                   
VFF/HVFF Integral Rated Temp: 60c , 105c Japan Cable Type  
 
Cable Type No. of Conductors Conductors Insulation  
Current Amp Cross Section Strands O.D. Thickness O.D.  
VFF & HVFF 2 7A 0.75 30 / 0.18 1.1 0.8 2.7X5.4  
12A 1.25 50 / 0.18 1.5 0.8 3.1X6.2  
15A 2 37 / 0.26 1.8 0.8 3.4X6.8  
All Dimensions in MM  
                   
                   
VCTF/HVCTF   Rated Temp: 60c , 105c Japan Cable Type  
 
Cable Type No. of Conductors Conductors Insulation  
Current Amp Cross Section Strands O.D. Thickness O.D.  
VCTF & HVCTF 2 7A 0.75 30 / 0.18 1.1 0.6 6.6  
12A 1.25 50 / 0.18 1.5 0.6 7.4  
15A 2 37 / 0.26 1.8 0.6 8  
3 7A 0.75 30 / 0.18 1.1 0.6 7  
12A 1.25 50 / 0.18 1.5 0.6 7.8  
15A 2 37 / 0.26 1.8 0.6 8.5  
All Dimensions in MM  
                   
                   
VCTFK/HVCTFK   Rated Temp: 60c , 105c Japan Cable Type  
 
Cable Type No. of Conductors Conductors Insulation  
Current Amp Cross Section Strands O.D. Thickness O.D.  
VCTFK & HVCTFK 2 7A 0.75 30 / 0.18 1.1 0.6 4.3X6.6  
12A 1.25 50 / 0.18 1.5 0.6 4.7X7.4  
15A 2 37 / 0.26 1.8 0.6 5.0X8.0  
All Dimensions in MM